CN
RION SCA118T

CURRENT TYPE SINGLE AXIS INCLINOMETER

Single Axis Inclinometer

Measure Range :±1~±180° optional

Accuracy: 0.03°

Resolution: 0.01°

Output current 4~20mA

Wide voltage input: 9~36V

Wide temperature working: -40~+85℃

Highly anti-vibration performance >2000g

  • Product Description
  • Scope of application
  • Parameter
  • Dimensions
  • Download

Product Description


SCA118T is a standard industrial output type single axis inclinometer with a standard current output of 4~20mA, which can transmit up to 2000 meters over long distances. The output signal has strong anti-interference and is professionally applied to construction machinery equipment working in harsh environments. The product is produced using the latest MEMS sensor production process, and the temperature error and nonlinear error are accurately compensated and corrected. The highest accuracy in a small range can reach 0.02° (for more accuracy indicators, please refer to the product performance table), high accuracy, Small size, high packaging technology, good ability to withstand shock and vibration. The product has built-in anti-RF and anti-electromagnetic interference circuits, which is especially suitable for underground trenchless machinery and other harsh industrial environments. In addition to having better technical parameters than ordinary products in the market, the product also uses various measures such as high-end application-level MCUs, three-proof PCB boards, imported cables, and wide-temperature shielded metal shells to improve the reliability and stability of the products. Industrial grade.


Scope of application

Underground Drilling Rig Attitude Navigation

Bridge and Dam Monitoring

High-altitude platform safety protection

Medical device angle control

Engineering vehicle leveling

Shield pipe jacking application

Inclination-based orientation measurement

Geological equipment tilt monitoring

Mining machinery, oil drilling equipment

Equipment level control

Alignment Control, Bending Control

PARAMETERS

SCA118

CONDITION

PARAMETER

UNIT

Measure range

 

±10

±30

±60

±90

±180

°

Measure axis

 

X

X

X

X

X

Axis

Zero output

0° output

12

12

12

12

12

mA

Resolution

 

0.01

0.01

0.02

0.03

0.05

°

Measure accuracy

@25℃

0.03

0.05

0.06

0.08

0.1

°

Long term.stability

 

0.05

0.05

0.05

0.05

0.05

°

Zero Temp.coefficient

-40~85℃

±0.006

±0.006

±0.006

±0.006

±0.006

°/℃

Sensitivity temp-coeffi

-40~85℃

≤100

≤100

≤100

≤100

≤100

ppm/℃

Power-on start time

 

0.5

0.5

0.5

0.5

0.5

S

Response time

 

0.02

0.02

0.02

0.02

0.02

s

Response frequency

20Hz

EMC

According to EN61000 and GBT17626c

MTBF

≥50000 hours/times

Insulation Resistance                  

≥100 MΩ

Impact resistance

100g@11ms、3 AxisDirection (HalfSinusoid)

Anti-vibration

10grms、10~1000Hz

Protection grade

IP67

Cables

Standard as 1-meter length, wear-resistant, oil-proof, wide temperature, shielded cable 4 * 0.4mm2

Weight

≤220g (including 1 meter cable)

ELECTRICAL PARAMETERS

PARAMETERS

CONDITION

MIN

TYPICAL

MAX

UNIT

Power supply voltage

Standard

9

12、24

36

V

Working current

 

 

50

 

mA

Output overload

Resistive

 

400

1000

Working temp.

 

-40

 

+85

Store temp.

 

-40

 

+85

Dimensions

Size description

  • Shell size

    L94×W40×H26mm

  • Installation size

    L78×W29×H4.5mm

  • Mounting screws

    4 M6 screws

Specifications and Software

* Please contact the online sales engineer to obtain the product specification of Rion, or email sales@rion-tech.net to obtain it.